Door Underbench Safety Cabinet

The 90-minute fire resistant safety cabinets that are compliant to the standard EN 14470-1, have been tested successfully until 105 minutes. They allow storing your flammable products safely, and delaying the spread of the eventual fire in the cabinet, while waiting for rescue intervention.

The 90-minute fire resistant safety cabinets that are compliant to the standard EN 14470-1, have been tested successfully until 105 minutes. They allow storing your flammable products safely, and delaying the spread of the eventual fire in the cabinet, while waiting for rescue intervention. The fire proof cabinet will work like this(click on link below).

FIRE PROOF CABINET

FIRE-RESISTANT SAFE FOR DOCUMENTS

Data Sheet -AD 79DE

CONFORMITY

Tested and approved according to NT FIRE 017-90 Paper norm (90 minutes Fire resistance).

ADVANTAGE –

Allow to store in safety your documents and protect them against fire and robbery. – 90 minutes Fire resistance according to ISO 834 heating curve

OPTIONS?

Additional shelf, contact us.

Shelf for suspension files. –

Doors with different color possibilities on 794DE and 795DE models ?

frame and shelves in white (RAL 9010); doors in yellow (RAL1023)

Fireproofing indoors (wood, gypsum, wall, or ceiling)

INCA DC333 The expandable fireproof paint in water base for both interior and exterior. DC333 will expand rapidly to be dense foams as a barrier to stop the fire spread effectively. DC333 contents the special Veova latex resin, nanometer inorganic materials and water proofing agent which will affect the anti-dust on the surface of coating layers to maintain the characteristics of coating not be decomposed by water. Of course, non-toxic, environment friendly and smoke spreads limited are the characteristics of DC333.

WIRELESS FIRE PROTECTION SYSTEM​

The NOFIQ fire prevention system is a complete fire prevention system. The system has been especially designed for detecting, alarming and extinguishing a fire in enclosed compartments containing electrical components (maximum 1500 Volt DC and 1000 Volt AC).

The NOFIQsystem is primarily meant for objects that cannot be entered by humans. The system is pre-eminently suited for application in:

  • switch cabinets
  • patch cabinets
  • meter boxes
  • computers

The NOFIQ system is used to detect a fire at its source in its earliest stadium and to extinguish this fire.Already in the initial phase of fire, the detection and extinguishing component will alarm the surrounding area and send a message to the alarm management station. If a fire really ignites, the extinguishing component will extinguish the fire thanks to the built-in aerosol fire-extinguishing component. In the meantime the alarm management station has notified the fire brigade or another fire-fighting service.The NOFIQfire prevention system uses aerosol fire-extinguishing components.The aerosol fire-extinguishing components are pre-eminently suited for extinguishing fires of the following fire classes

  • :A, Solids
  • B, Liquids
  • C, Gasses
  • F, fat and oils

FIRE RETARDANT CABLE coating (intumiscent)​

DC310 fireproof cable coating for wires and cable is developed using innovative intumescent. It is a heavy duty intumescent coating for interior applications used to effective prevent flame spread. When fire occurs the coating will rapidly intumesce to form a foam char layer that prevents fire propagation. DC310 fireproof cable coating is water based, asbestos-free,non-halogenated and environment-friendly.

STEEL STRUCTURE FIRE PROOFING

As a coating or paint for steel structure, fireproofing may provide a good measure of corrosion protection.

Vermiculite fireproofing Coating by means of a vermiculite spray which is a passive resistant and highly stable fire protection coating for the steel structure.

Intumescent paintings promise better corrosion protection than concrete due to their low permeability, there have been reports of severe corrosion under fire protection with these materials.rials. Intumescent epoxies are complex patented materials.

Fire Resistant Spray For Fabric / Textile

Interior furniture and synthetic fabrics are the number One contributing factors to fire spread and smoke generation today. DC68 is a water-based fire proofing spray that is non-toxic, hypoallergenic, colorless and absorbent fabric or material.

DC68 Spray to protect retards fire and prevents the spread of flame over the treated area. DC68 reduces smoke generation which increases visibility and the time to escape a fire situation. Smoke is the leading cause of depth in fires and using DC68 significantly increases survivability.

DC68 Spray to protect is highly effective when applied to curtains, drapes, carpets and rugs, decorations, paper products, wall paper & coverings, table cloths, or any water absorbent fabric.

DC68 Spray to protect will not affect look, feel or ventilation .

Qualities of most materials treated, however it is recommended to test a small area before applying to entire surface.

Fire Retardant Cable Coating (Ablative)

Features:

  • Water base material
  • Non-halogenated
  • Asbestos free
  • High solids
  • Remain flexible after cured
  • No cable derating
  • Water resistant
  • Interior and exterior application
  • FM approved

Fire Sealing Electrical Box with Putty pad

Putty Pad is a moldable fire-rated putty material with intumescent properties. When exposed to flames or high temperature will prevent the spread of flames, smoke, and toxic gases through openings in fire Rated walls and partitions. INCA Putty Pad is designed to protect electrical boxes or other penetrants with up to 2-hour fire resistance and is easy to install, reuse or retrofit.

Fire Sealing Curtain wall joint

On installing, Curtain Wall joint seal, it act as a fire barrier,retarding the progress of fire, smoke and heat between floors of multi?storey buildings. The product is designed to be installed between the edge of the concrete floor slab and a fire rated spandrel panel to provide floor to floor fire separation.

Features

  • Floor thickness above 114 mm
  • Joint gap of 200 mm
  • Fire rating 3 hours F, 2.5 hours T
  • The sealant is approved acoustic
    as per ASTM E90.
  • Aluminum or GI flushing is made